Technical Information
[Load Ratings and General
Technical Info]
[DT/PE and PEM Series Specification/Installation
Guide]
[Installation in Grass, Dirt or Gravel]
[Installation in Concrete and Pavement]
|
|
Load Ratings and General Technical Info
Test Data
| Cover
Type |
Cover
Rating |
Test
Data |
| Plastic |
5,000# |
10" x 10" |
| Steel |
6,000# - 10,000# |
10" x 10" |
| Polymer Concrete |
10,000# - 20,000# |
10" x 10" |
PenCell’s manufacturing facility is ISO 9001:2000
compliant and certified.
PenCell’s Plastic boxes and plastic covers are for
locations that are non-traffic or may have an occasional, non-deliberate light
vehicle exposure. PenCell’s plastic enclosures with plastic lids should not be
placed in walkways.
PenCell’s Polymer Concrete and Steel covers when used on
our plastic boxes, can be placed in locations that may have an occasional but
non-deliberate light to heavy vehicle exposure.
NOTE: No PenCell product should be placed in a full
traffic or deliberate vehicle traffic area. This would include all areas
requiring an “H” type rating.
|
|
Material Information
Testing meets and exceeds:
H.D.P.E.
Thermal Shock - ASTM D-756
Water Absorption - ASTM D-570 Section 6.1
Weathering - ASTM D-822 Section 6.2 Procedure A
Chemical Resistance Tests - ASTM D-543
Flammability - Union Carbide Test Method WC-73-D-1
ROTO MOLDING
Impact test per (ARM) = 68 ft.-lb., 400 C, F50
Flexural Modules (ASTM D-790) = 115,000 psi
ESCR = 1000 hours, F50, condition B, 100% Igepal
Flammability (UL) = UL 94 HB
Heat Distortion (ASTM D-648) = 64, 66 psi, degrees C
POLYMER CONCRETE
Flexural strength
Impact energy
Freeze/Thaw resistance (2500 cycles)
Water Absorption
Chemical Resistance - per ANSI/SCTE 77
|
|
|